Engineered Heat Rejection for HVAC-R, Data Centers and Industry
Free cooling, process heat rejection and energy recovery all depend on how efficiently heat is transferred to ambient air. Undersized or inefficient dry coolers increase energy consumption, raise operating costs and limit system capacity during peak ambient temperatures.
Wieland Dry Coolers are engineered to minimize energy consumption, reduce environmental impact and deliver consistent performance throughout the unit’s entire service life, with material and configuration choices matched to the specific application.
Benefits at a Glance
- High energy efficiency
- Low environmental impact
- Reliable performance
- Flexible design
- Easy installation and maintenance
Product Variants – Optimized for Dry Cooling Solutions
Our Dry Coolers combine efficient heat exchange surfaces with a compact and robust design to ensure reliable performance. Each unit is adapted to its specific application, with a wide choice of materials and configurations to meet different operating requirements and environmental conditions.
Flat Configuration – Optimized models for easy maintenance and long-term operation
Available in vertical or horizontal air flow configuration.
Capacity: from 20 kW to 1000 kW
Fans: from 1 to 14 fans
n° fan lines: 1
Fans: 1–5
n° models: 230
Capacity: 20–500 kW
n° fan lines: 2
Fans: 4–14
n° models: 190
Capacity: 80–1000 kW
V Shape Configuration – Maximum capacity with a reduced footprint
Capacity: from 50 kW to 2000 kW
Fans: from 1 to 20 fans
n° fan lines: 1
Fans: 1–8
n° models: 80
Capacity: 60–1000 kW
n° fan lines: 1
Fans: 1–10
n° models: 100
Capacity: 70–1300 kW
n° fan lines: 2
Fans: 4–16
n° models: 70
Capacity: 230–1650 kW
n° fan lines: 2
Fans: 4–20
n° models: 90
Capacity: 230–2000 kW
Adiabatic Configuration – Specifically created and optimised for adiabatic system
Capacity: from 50 kW to 2500 kW
Fans: from 1 to 11 fans
Wieland Selector – find the ideal air-cooled solution for your project
In just a few steps, configure the dry cooler that best matches your operating conditions and performance requirements – with accurate selection, fast results and complete documentation.
Adiabatic Cooling – Smarter Cooling, Lower Consumption, Higher Performance
In hot ambient conditions, standard dry coolers lose cooling capacity exactly when demand is highest. Wieland’s adiabatic system pre-cools incoming air through water evaporation before it reaches the heat exchanger, using pad, spray or high-pressure atomization systems. This significantly increases cooling capacity and efficiency during peak temperatures while minimizing water and energy consumption. Intelligent control activates the adiabatic system only when ambient conditions require it.
Adiabatic Air Pre-Cooling: Before reaching the heat exchanger, ambient air is pre-cooled by water evaporation through either spray nozzles or an adiabatic media PAD, reducing the inlet air temperature.
Efficient Heat Exchange: The pre-cooled air flows across the heat exchanger coil, absorbing heat from the process fluid and enhancing heat rejection efficiency.
Process Fluid Cooling: The dry cooler removes heat from the process fluid, reducing its temperature before it is returned to the process or chiller system.
Coatings and Materials
Coil Coating Solutions – The Right Protection for Every Environment
Our range of protective coatings is engineered to ensure long-lasting performance and reliability of the heat exchanger in any operating condition, from standard HVAC to the most aggressive environments.
| Coating / Treatment | Description | Key Benefits | Corrosion Resistance | Fin surface |
| BARE Aluminium | Aluminium fins. | Standard application. | Standard | |
| HYDROPHILIC Aluminium | Hydrophilic coating that reduces water adhesion and improves drainage. | Improved water drainage. Reduced frosting risk. | Standard Plus | |
| PRE-PAINTED Aluminium | Aluminium fins pre-painted for enhanced protection. | Additional protection. | Medium | |
| BLYGOLD® Epoxy-polyester | Epoxy-polyester coating with excellent corrosion resistance. | High corrosion resistance. Long service life. | High | |
| HERESITE® Advanced polymer | Advanced polymer coating for superior protection in harsh environments. | Very high corrosion resistance. Ideal for severe environments. | Very High | |
| ELECTROFIN® Epoxy | Electrofin® coating with cathodic protection for extreme durability. | Maximum corrosion protection. Extended durability. | Very High |
Tube Material Options
Choose the optimal tube material to match your performance requirements and environmental conditions.
| Material | Best suited for |
| Copper Tubes | Industry-standard solution combining excellent thermal conductivity and proven reliability |
| AISI 304 Stainless Steel | Process applications and mildly aggressive fluids |
| AISI 316L Stainless Steel | Marine, chemical and demanding industrial applications requiring maximum corrosion resistance |
Typical Applications
Wieland Dry Coolers are suitable for a wide range of commercial and industrial cooling applications. Typical uses include:
- HVAC-R – Efficient and reliable cooling solutions for comfort applications,
- Data Center – High performance and redundancy for mission- critical systems,
- Industrial Cooling – Process cooling and heat recovery for industrial processes,
- Power Generation – High-capacity heat rejection for power and cogeneration plants.





